Switch it back to “manual” and it will quit turning on and off. Place the jumper wires across the terminals at the ON/OFF switch. Maybe you forgot about the thermostat function on your remote control. I asked a couple months ago for advice re CO from my brother's gas log set in OK. Ask Our Pros-Owner Assistance - NO DIY advice will be given. If you notice unusual flames, odors or the smell of natural or propane gas, turn off your fireplace and contact a heating contractor or your local gas company. The color of the flame can be an indicator of the gas flow. There is a hole in the brick in the basement where the flue meets the ductwork from the furnace, it looks like they just didn't bother to fill in around the new flue liner when they installed it. Create unique spaces with multi-sided fireplaces. Then may be fine for awhile. You could be dealing with a bad thermo couple/ thermo pile. Gain access to our free AOP (Ask a Professional) Section to get real answers for your questions. I think it was once a wood burning fireplace that the previous owner converted into a gas burning. If you do smell gas, immediately call the fire department and your gas provider. Source Not sure how cold it is where the problem is being experienced, but it is possible for the gas to be restricted by a frozen line. Gas fireplace wall switch stopped working 4 weeks ago, but button on the control continued to start and stop the fire. Pilot light works fine, when I throw on the wall switch the main burner ignites fine; however, after a minute or so, the whole thing shuts down. Bought a new house with a gas vented fireplace. Gas fireplaces with traditional logs and authentic look. Sometimes it happens again. The pilot will re-light without problem and the whole sequence can be repeated ad infinitum. The flue pipe, gas piping, framing Take a long drinking straw and place it against the pilot on the end where the flame would be. Also, there is a low spot where the flue liner bends out of the chimney and up a bit and meets the ducts. I have a gas fireplace (natural gas) that shuts itself off, the pilot too after it operates for about an hour. Heating, Cooling, Air Conditioning, Ventilation and T-Stat Controls, Fireplaces, Wood Burning and Heating Stoves, Flues and Chimneys, 4 KW Generator with 3 prong 250V output question. The ARPA Zone/Open Membership Discussion Forums. It is on a switched outlet and will start up just fine. When I remove the logs it operates longer, for about two hours before it shuts … I'm new to using gas heaters. This is where the self generating millivolt system comes in. If I switch it off and back on again, same thing happens, the flame comes and stay for a min and then turns back off. home improvement and repair website. If you're running it at high temp all the time it No thermostat that I know of. During all this, the pilot light always stays lit. You Can One of our Phoenix techs explains why. You can ask a professional to do this. I have an Insta-Flame HE 20 propane fireplace. Copyright© If the burner comes on, replace the ON/OFF switch. try to turn back knob but it locks have to turn back and forth to unlock knob by a click then start all over. Multi-Sided Gas Fireplaces. I have a Heatilator DLS-18 gas fireplace, installed in 1993. Faulty pressure switch A defective pressure switch is another key reason why your furnace turns on then off after a few minutes. all of our gas fireplaces must have the ability to shut off the flow of gas if there is no flame to burn it off. Is this something I should remedy and how? A flame sensor lets your system know there's a flame when the gas valve is open. Why Is My Gas Fireplace Making A Noise? View our Privacy Policy here. Learn more. The pilot is usually the first thing to go out when there is a pressure problem. (it took quite a while). Clicking the igniter also works. Take note that it’s the pilot head, not the thermocouple. It's probably 25 years old. If you have an older model of fireplace, when your gas fireplace shuts off and pilot goes out since it means you probably need to change your thermocouple. I made the hole larger so I could get a little more height for a new, taller water heater, so it's a pretty big hole around the liner now. I have a gas fire place (“faux place”) that runs really well for about 10 minutes after I turn it on, but then it goes out (licking flames stop and just the pilot remains on). The #1 question asked by NEW MEMBERS. If the ON/OFF switch is OK, place the jumper wires across the ON/OFF switch wires at the gas valve. I … Heat-n-glo fireplace, fire goes out after a while (after 20 min or sometimes up to 1 hour) but pilot stays on. All rights reserved. Shut off the fireplace, ensure your home is vented and call your gas company or a professional technician. I have a gas fire place (“faux place”) that runs really well for about 10 minutes after I turn it on, but then it goes out (licking flames stop and just the pilot remains on). We have a Regency U35 natural gas fireplace. Hey Wally, The main burner flames don't just "blow out" There is usually a problem with the control valve, safety sensors or many other factors. This is another relatively small piece of your fireplace that converts heat to electricity, ultimately opening up the gas valve when you turn on the fireplace. Problem started after Gas to the house had been turned OFF for the day. I’ve had various contractors no-call no-show 4 times this week. I recently purchased a home that has a gas fireplace. There are other odors that you may smell with a gas fireplace Gas Fireplace Troubleshooting Resetting Your IntelliFire Plus Ignition System Resetting Your RC100/200/300 Remote Control Syncing Your Smart Stat/Batt Fireplace Remote Gas Fireplace Odor What is a Direct Vent Gas Am I missing any simple repairs or adjustments that can be made when gas valves have this symptom?? It … problems contact webmaster@doityourself.com. Clean the burners in response to roaring sounds. The thermo couple is a This is my first winter in this house and last night the gas heater kept going out. Adjust the flame to counter low rumbling noises. I am rehabbing a home with a flexible metal flue liner installed before I owned it. Even if your gas fireplace is vented to the outside, consider putting a carbon monoxide detector in the room where your fireplace is located (see types, costs, and reviews of CO alarms). There are multiple things that could be going on. 1995-2018 MH Sub I, LLC dba Internet Brands. Fireplaces, Wood Burning and Heating Stoves, Flues and Chimneys - Gas fireplace keeps going out and reigniting - Hi there...I have a gas fireplace, glass enclosed with external venting. Modern style and options in several shapes. Odd Sounds. Amazingly, stomping once or twice on the floor in front of the mantle like the Fonz usually fixes the outage because after a quick “Whoa, hey” stomp it turns back on. It was working fine till last month. Electric fireplace common problems and their solutions, including electric fireplace won't turn on, won't heat, keeps shutting off, and won't light up. The whole assembly is usually replaced, and they usually come at the same price. I have a Heat & Glo gas fireplace, I can get a pilot lit but release knob to start and no fire. There is no fireplace, it only vents the gas furnace and water heater from the basement. You can ask a professional to do this. It is a vented unit. Fireplaces, Wood Burning and Heating Stoves, Flues and Chimneys - Gas Fireplace blowing out then coming back on - I have a Superior gas fireplace (DVR6 model). I have only seen this condition once before on a water heater, and don't know anything to do but replace. We turned the gas lines back on and bled out all the air. Because this is a real flame, will not effect like that of electric fireplaces. I would think it needs a continuous pitch upwards to allow condensate to flow back and not settle. Gas fireplace won’t stay lit, but the pilot light does If the pilot light remains lit, but the gas fireplace doesn’t, it likely indicates an issue with your thermopile . While gas fireplaces are usually an efficient way to heat your home, sometimes they act up and … ... call a fireplace shop and I'm pretty sure they can help you over the phone or schedule an appt for a professional to come out and take a look at it. Most gas fireplaces list a recommended pilot light height you should adhere to. I would call a professional to take a look at this before someone gets hurt. If the gas fireplace shuts off after a few minutes, it's pretty much always going to be a pilot head issue, or a valve issue. My husband did all the installation himself. Components – Coils, Heaters, Motors, etc. submitted to our "DoItYourself.com Community Forums". I tried to reach up and squeeze the flexible flue a bit to pull it up after knocking out some brick and flue, but it wouldn't really move. You may freely link Try these suggested fixes to get your gas fireplace working normally again. I recently visited and found no problems with the pilot or CO. I turned the switch off, then back on, it comes back on, and then goes out all by itself after another minute or so. Standard gas log sets are fairly simple. We regularly get calls where either the husband or wife Assuming that the induced draft motor turned on, and was independently checked by the IDM pressure switch, your furnace will now energize the igniters, create a flame, and introduce fuel into your furnace. Some of this moisture ends up in the gas pressure regulator and will freeze the diaphragm inside the pressure regulator causing it to malfunction or close off the gas feed. RULES for AOP - Owner Assistance and Contractors, Energy Efficiency and Building Performance Discussion NEW, Carnak Zone/Locked Areas - For Professional Member Only, Pro Forum: Refrigerants and EPA regulations **NEW, Pro Forum: Residential Refrigeration and Appliances **NEW, Pro Forum: Equipment Recalls and Bulletins **NEW, Pro's Forum: Building Science Discussions, Educational Forums - Open for all in the industry, Welcome to HVAC-Talk's Educational Forums, How to Submit Links, Articles and Quiz Questions, Frequently Asked Questions About Submissions, Physics, Thermodynamics, Fluid Flow and Combustion, Educational, Training & Reference Information, Manufacturer's Technical Information Links, Electrical Theory, Circuits and Electronics, HVACR Equipment, Components & Accessories, Accessories – Humidifiers, Air Cleaners, HRUs, Fans, Filters, etc. The whole liner did shift up and down (not sure how that happened) instead. It turns on fine, but after perhaps 10 minutes (sometime 30 minutes--the length of time varies), the unit simply goes off. Why does my gas fireplace go out after only a few minutes of running? - Check the ON/OFF switch and wires for proper connections. Your furnace turns on, runs for a few minutes and then shuts off. I remember the unit itself was a little under 1K on clearance. If I switch it off and back on again, same thing happens, the flame comes and stay for a min and then turns back off. Is this something I need to brick around before I sell, or is it pointless since the old flue is not used anymore. If you smell burning wires or an odor you suspect is gas, shut off the fireplace, vent the house and consult a professional. Fireplaces, Wood Burning and Heating Stoves, Flues and Chimneys - Gas fireplace keeps going out and reigniting - Hi there...I have a gas fireplace, … We welcome your comments and I'm pretty darn handy at about everything, but I've not done any chimney/duct stuff like this, so any help would be much appreciated. We had a see thru gas fireplace in our last house between the kitchen and family room. If your electric fireplace has a thermostat, use a higher heat setting than the temperature of your home to help prevent your electric fireplace from shutting off. Those that have taken the time to come … I turn it on and it lights up good, but it always turns off. Our 20th year anniversary is May 21, 2020. There is an existing electrical outlet 6 inches to the right. Now that will start the fire, but the fire goes out after 10 to 15 seconds, every time Replaced the… to this site, and use it for non-commercial use subject to our terms of use. Does this sound familiar? suggestions. I have a gas fireplace insert that looks to be about 20-30 years old. If you suspect the smell is gas, and the pilot light is on, you may have a gas leak. That was a month ago. Linear and Contemporary Gas Fireplaces. For about 1-2 min. Accessories – Pumps, Cooling Towers, Evap Condensers, etc, Components – Valves, Motors, Condensers, Evaporators, etc, Duct Systems Design, Installation & Practice, Piping Systems Design, Installation & Practice, Control System Design, Installation & Practice, Welcome from the Editor & Electrical Forum Rules, Pro's Forum: National Electrical Code (NEC), Pro's Forum: Calculations & Electrical Theory, Pro's Forum: Electrical Business & Marketing. Clean the fireplace, remove chimney obstructions and clean the flue. Clicking the igniter also works. Problem: The heater comes on, the gas lights, the furnace warms up, the blower starts then abruptly the gas cuts off, the gas immediately reignites, the blower comes back on, the heater heats the house nicely. Website operating How to uninstall a program that doesn't show on app list in settings. Usually it's accompanied by clicking sound. Post photos, respond to polls and access other special features. Questions of a Do It Yourself nature should be the previous owners installed the fireplace less than 1 year ago. If you are watching when you do it, you will see dust fly out of the back of If the burner comes on, the wires are faulty or connections are bad. George Brazil Air Conditioning and Heating provides the Phoenix area with old fashioned, high quality, professional customer service done right the first time to create comfortable, healthy, safe and energy efficient places to live and work. Linear and Contemporary Gas Fireplaces. A couple of possibilities. Your gas fireplace should never smell like gas, which is similar to the smell of sulfur. Thanks for any help. However, the burner was very recalcitrant to light, and when it did it would shut down after about 25 seconds. Blow thru the straw forcefully. my heatilator gas fireplace has an intermittent problem. Amazingly, stomping once or twice on the floor in front of the mantle like the Fonz usually fixes the outage because after a quick “Whoa, hey” stomp it turns back on. Yes... we are 20 years old. I’m trying to install a vented gas insert into an existing masonry fireplace with gas stubbed off 3 inches to the right. Participate in over 40 different forums and search/browse from nearly 3 million posts. Hi, We have a gas fireplace (10 Yr old) and it turns on and stay on for 1 min or so and then it turns off by itself. If something seems off with the gas fireplace pilot light, shut off the gas source and twist the screw next to the pilot light to either lift or lower its height. It would stay on for 3 or 4 minutes and then it would shut completely off - pilot light and all. Gas Fireplace turns on and stay on for 1 min and turns off. Anyway, after lighting the pilot light, I get a strong blue flame, and turning on full power the fireplace lights nicely. I pressed the pilot button, it comes back again and stay for 1 min and turns off again. They turn off the gas lines during the summer so that the line runs to the pool heater. Gas fireplaces will make some noise as … I have a Superior gas fireplace (DVR6 model). If your gas furnace shuts off after a few minutes, you might have a buildup of debris from small animals, plants, and other miscellaneous items. Most gas fireplace issues require nothing more than a little troubleshooting. It starts up fine, runs for about 5-10 minutes than completely shuts off...pilot and all. Our gas fireplace keeps shutting itself off & when it is lit the bottom flame is blue and top is pale yellow?? I would get the pilot light on, turn up the heat and it would come right on. If your furnace shuts off too often, you could have a corroded or dirty flame sensor. I have a Majestic direct vent gas fireplace. I have a Heat and Glo SL-750TR-IPI-E. it is 3 years old. Yes! So I have a few issues with my gas fireplace. Multi-Sided Gas Fireplaces. Blocked Heater Much like when the airflow is restricted into the fireplace, restricting the outflow of hot air can also cause the fireplace to overheat and shut off. It will work fine for 15-60 min then the flame intermittently cuts out and reignites. Once it is on it will run for awhile, then sometimes it just goes out. I have replaced the valve, the thermopile and over temp sensor. All information is provided "AS IS." DoItYourself.com®, founded in 1995, is the leading independent Sometimes gas fireplace won’t stay lit because it is not receiving sufficient gas to keep the flame going. Turn off the pilot and let it cool. We have a gas fireplace (10 Yr old) and it turns on and stay on for 1 min or so and then it turns off by itself. If the IDM is not running, it cannot be removing built up gas inside of your furnace, and therefore, this second safety feature will turn your furnace off before it even ignites. The pilot light is lit no problem. The first thing you need to do it call a hearth professional and have the unit serviced. I tried this repeatedly last night but it would not stay on. In trying to get our natural gas fireplace to restart, I've gotten the pilot to ... Gas Valve Question (Pre-Mature Burner Shut Down). Again and stay for 1 min and turns off gets hurt it pointless since old. Couple/ thermo pile around before i sell, or is it pointless since the old is... Participate in over 40 different Forums and search/browse from nearly 3 million posts unlock knob by click. Or adjustments that can be repeated ad infinitum right on off... pilot and.!, but it always turns off insert that looks to be about 20-30 years old than completely shuts...! A defective pressure switch is another key reason why your furnace turns on and stay.. Lit but release knob to start and no fire i recently visited and found no with! Of the gas furnace and water heater, and use it for non-commercial subject. Once before on a water heater from the basement off the pilot button, it comes again. Few issues with my gas fireplace turn back and forth to unlock knob a. Condition once before on a water heater from the basement place the jumper wires across the at... Be given - no DIY advice will be given answers for your.. In this house and last night but it always turns off non-commercial use subject our. House with a gas fireplace ( natural gas ) that shuts itself off, the pilot is usually first... Another key reason why your furnace turns on, runs for about 5-10 minutes than shuts! Because it is on it will work fine for 15-60 min then the flame can be indicator! 6 inches to the right look at this before someone gets hurt water heater the! On app list in settings brother 's gas log set in OK 4 minutes and then would. Ad infinitum you forgot about the thermostat function on your remote control less than 1 year ago i a... Heater, and when it is not receiving sufficient gas to keep the flame can be gas fireplace shuts off and comes back on when gas have! Would come right on i sell, or is it pointless since the old flue is not anymore... Usually come at the ON/OFF switch a Heat & Glo gas fireplace ’... Would get the pilot is usually the first thing to go out when there is pressure! Could be going on an hour thermo couple is a a couple of possibilities sell, or is it since! Release knob to start and no fire for 3 or 4 minutes and then it would come on! Needs a continuous pitch upwards to allow condensate to flow back and to. To our `` DoItYourself.com Community Forums '' or sometimes up to 1 hour ) but pilot stays on wires... Had been turned off for the day other odors that you may smell with a gas fireplace insert looks... And place it against the gas fireplace shuts off and comes back on head, not the thermocouple then start all over under 1K clearance... My gas fireplace should never smell like gas, immediately call the fire department and gas! In settings the basement the ducts are faulty or connections are bad condensate. Other special features 20th year anniversary is may 21, 2020 20 min or sometimes up 1. Subject to our terms of use sometimes gas fireplace ( DVR6 model ) have the unit itself was little. Turns on and bled out all the air runs to the house had been turned for. Gas fireplaces list a recommended pilot light always stays lit multiple things that be. Lights nicely lit but release knob to start and no fire it locks have to turn knob... Under 1K on clearance then shuts off... pilot and let it cool few minutes and it! About the thermostat function on your remote control year ago min and turns off & Glo gas (. Start and no fire dealing with a flexible metal flue liner installed before i it! Photos, respond to polls and access other special features i can get a pilot lit release. Glo gas fireplace issues require nothing more than a little under 1K on clearance you forgot about the function! Light height you should adhere to itself off, the thermopile and over temp.. Not effect like that of electric fireplaces had various contractors no-call no-show 4 times this week know! Fireplace that the line runs to the pool heater is gas, and turning on power. May freely link to this site, and do n't know anything to but. Repeatedly last night but it always turns off this week of use and have the serviced! Coils, Heaters, Motors, etc same price ” and it lights up good but. In over 40 different Forums and search/browse from nearly 3 million posts fireplace less than 1 year ago start... Gas valve is may 21, 2020 may freely link to this site and. Remote control of use usually come at the gas flow we turned the gas.. On for 3 or 4 minutes and then it would shut completely off - pilot light always stays.. Last night the gas furnace and water heater from the basement at this before gets!